23-2
Local -601- Internal memory error in port parameters
Access server defaults in effect
Explanation: Parameters in the access server ports permanent database are corrupt and
factory-set defaults were used during port login.
Step Action
1 Use the CHANGE PORT command to reset the port characteristics to values of your
choice.
2 If the error message appears again, reset the port characteristics using the software
reset switch on the access server.
a. Remove power from the access server.
b. Press and hold the reset switch while you turn on the power to the access server.
c. Continue to hold the reset switch until the system o.k. LED starts to flash.
d. Use the CHANGE PORT command to reset the port characteristics to values of
your choice.
3 If this action fails to correct the problem, the access server memory that stores the port
characteristics is faulty. Refer to Chapter 29 for service information.