INSTALLATION REQUIREMENTS/SPECIFICATIONS
2-8
JAM Output: Collisions are propagated through the
network using the JAM signal of an
alternating pattern of 1's and 0's in
accordance with 802.3 specifications for a
repeater unit.
Fragment Extension: Packet fragments are extended to a
minimum of 96 bits using the JAM [1,0].
Fault Protection: Each segment will disconnect itself from
the other segments if 31 consecutive
collisions occur, or if the collision detector
of a segment is on for longer than
approximately 110 µs. This fault
protection will reset automatically after
one packet is transmitted/received onto the
fault protected segment without causing a
collision.
INTERFACE CONNECTORS
Network (Twisted Pair) Interface
Type: Internally Crossed Over RJ-45 Connector
Pin-out for RJ-45 Connector
Pin 1 RX+ 5 No Connection
2 RX- 6 TX-
3 TX+ 7 No Connection
4 No Connection 8 No Connection