6-1
CHAPTER 6
ELS10-26 MIB
The Cabletron MIB {enterprise 97} is divided into several groups of
parameters. The individual groups are described in the subsections
below.
The MIB tree prefix for reaching the private enterprise ELS10-26
MIB is:
1.3.6.1.4.1.97.
6.1 SYSTEM GROUP
sigma {enterprise 97}
sys {sigma 1}
The System Group contains those parameters which are likely to be
applicable to Fast Network product lines. A detailed description of
the parameters follows.
sysID {sys 1}
Integer Read-Only
An integer which serves to identify the type of hardware platform.
This document describes the es-1xe-bridge, which uses the value
(7) for sysID. Special third-party versions of the ELS10-26 may use
different values (3, 4,
or 5).
sysReset {sys 2}
Time Ticks Read-Write
The time, in centiseconds, before the ELS10-26 should reboot. A
GetResponse value of zero indicates that no reboot time has been
specified.